Technical Data

  • Control: Force-pilot operated, no pressure difference required.
  • Design: Piston.
  • Connection: Flange DN15 – DN50 (EN 1092-1 Form B1/B2).
  • Installation: Actuator upright.
  • Pressure range: 0–40 bar (model-dependent, see table).
  • Media: Clean, neutral gaseous and liquid media.
  • Max. viscosity: 22 mm²/s.
  • Temperature range:
    • Medium: -60°C to +80°C.
    • Environment: -55°C to +50°C.
    • ATEX: -55°C to +40°C (+60°C, depending on coil).
  • Body: Stainless steel 1.4581.
  • Internal parts: Stainless steel.
  • Sealing: PTFE.
  • Supply voltage: AC~ 24V, 110V, 230V; DC= 12V, 24V (others on request).
  • Voltage tolerance: -10% / +10%.
  • Power consumption:
    • S802 = 18 Watt, .808 = 24 Watt.
    • S322 = 21 Watt, .328 = 24 Watt.
    • S242 = 26 Watt, .248 = 30 Watt.
    • S272 = 60 Watt, .278 = 30 Watt.
    • S352 = 80 Watt, .358 = 75 Watt.
  • Protection: IP65 (DIN 60529).
  • Duty factor: 100% ED-VDE 0580.
  • Connection: Terminal box.
  • Ex-proof: 2014/34/EU (ATEX).

Series K37 Cryogenic 2/2-Way Solenoid Valve (NC), Pilot-Operated Flange DN15 – DN50, 0–40 bar

The Type K37 2/2-way force-pilot operated piston valve is designed for neutral gaseous and liquid media and operates at extreme temperatures from -60°C to +80°C. Normally closed (NC) as standard, optionally normally open (NO). The force-pilot design requires no pressure differential and closes by spring force when de-energized. The stainless steel housing (1.4581) and PTFE seals ensure durability and reliable sealing. Available with flange connections DN15 to DN50 (EN 1092-1 Form B1/B2) and a pressure range up to 40 bar. IP65 enclosure and ATEX certification make it suitable for industrial environments.

Advantages

  • Long service life due to high-quality materials.
  • Reliable and sturdy sealing.
  • Flange connections for industrial applications.
  • IP65 protection for demanding environments.
  • ATEX certified for explosive areas.